Related Experiment Video
Updated: Jun 9, 2025

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
Elimination of mutagenic contaminants from water using cellulose bearing ferrous-phthalocyanine
Kayoko Sano1, Yuka Soga2, Kaori Ohta1
1Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, 700-8530, Japan.
Background:
We previously investigated methods for separating mutagenic contaminants from aqueous solutions using cellulose-bearing covalently bound trisulfo-Cu-phthalocyanine (blue cotton and blue rayon). Mutagenic contaminants with three or more fused aromatic rings in their structures were adsorbed onto blue cotton and rayon. Since Cu-phthalocyanine is considered an unsuitable absorption ligand for byproducts of water chlorination, such as 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (Mutagen X or MX), we investigated the development of a new material for the elimination of MX from aqueous solvents.
Results:
We selected green cellulose powder bearing ferrous phthalocyanine (FePh), hereafter referred to as green cellulose or GP, as the candidate material. GP is composed of cationized cellulose (white cellulose, WP) and FePh tetracarboxylic acid. The mutagenicity of MX dissolved in buffer or dimethyl sulfoxide (DMSO) solution significantly decreased after treatment with GP. The effects of GP on the elimination of MX from the solvent were very close to being expired after 70 cycles of repeated adsorption of the same GP, and the capacity of GP for MX removal was estimated to be exhausted after 120 cycles of repeated adsorption based on the extrapolation of the obtained result; thus, the interacting ligands on GP may be saturated after complete MX adsorption. The mutagenicity of MX dissolved in aqueous buffer significantly decreased after treatment at pH7.4 but not at pH 4.0. Since MX is dissociated to be the anionic form at pH 6 or higher, the negative charge of MX in the buffer at pH 7.4 may interact with the positive charge of ferrous ions in GP to create a linkage between MX and GP. After GP adsorbed MX, mutagenicity was extracted with water or acetonitrile and recovered in the eluent. Thus, the reversible interaction between MX and FePh may have caused adsorption of MX onto GP.
Conclusion:
GP could be used as a new eliminator and recovery agent for MX in chlorinated drinking water. Developing new materials for the removal and recovery of agents for the detection of mutagenic contaminant-related chlorination in water is beneficial for environmental health.
More Related Videos
09:27Immobilization of Multi-biocatalysts in Alginate Beads for Cofactor Regeneration and Improved Reusability
Published on: April 22, 2016
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014