Related Experiment Video
Updated: Jun 9, 2025

07:54
Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
19.7K
Altered ventricular repolarisation dynamic: the missing link between obstructive sleep apnoea and sudden death?
Karim Benali1,2, Kanchan Kulkarni2, Frederic Roche3
1Cardiology Department, Saint-Étienne University Hospital, INSERM, SAINBIOSE U1059, Jean Monnet University, Saint-Étienne, France.
ERJ Open Research
|October 29, 2024
Abstract:
Research is needed to explore the broader links between oxygen desaturation episodes, ventricular repolarisation instability and genesis of malignant arrhythmic events https://bit.ly/3WeQNHy.
Related Concept Videos
Sleep Apnea
130
Sleep apnea is a condition where breathing stops intermittently during sleep, often leading to significant health issues. Each episode can last from 10 to 20 seconds or more and is frequently accompanied by a brief arousal from sleep. This disturbance, largely unnoticed by the individual, can lead to severe daytime fatigue. Commonly, individuals seek help after being informed by their partners about loud snoring and noticeable breathing pauses during sleep.
The condition is more prevalent among...
The condition is more prevalent among...
130
Sleep-Wake Cycles
1.2K
Sleep is an essential physiological process vital to maintaining overall well-being. The reticular activating system (RAS), a network of neurons in the brainstem, regulates wakefulness and sleep. While it may seem passive, sleep consists of distinct cycles, each with its unique characteristics and functions. Two key sleep phases are non-rapid eye movement (NREM) and rapid eye movement (REM).
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge:
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge:
1.2K
Dysrhythmias IV: Characteristics of Bradyarrhythmias
3
Bradyarrhythmias are cardiac rhythm disorders characterized by a slower-than-normal heart rate, typically defined as fewer than 60 beats per minute. Some of which are discussed here:Sinus BradycardiaSinus bradycardia presents a heart rate lower than 60 beats per minute, with a regular rhythm originating from the SA node. The ECG typically shows normal P waves preceding each QRS complex, a normal PR interval (0.12 to 0.20 seconds), and a normal QRS duration (0.06 to 0.10 seconds).First-Degree AV...
3
Coronary Artery Disease III: Clinical Manifestations
3
Coronary Artery Disease (CAD) is a primary health risk worldwide, leading to significant morbidity and mortality. The condition arises from the buildup of atherosclerotic plaques within the coronary arteries, resulting in diminished blood supply to the heart muscle.The clinical manifestations of CAD vary widely, from asymptomatic stages to severe, life-threatening conditions. Understanding these manifestations is crucial for early diagnosis and effective management.Angina Pectoris: The Warning...
3
Mechanism of Cardiac Arrhythmias
892
Arrhythmias are irregular heart rhythms occurring when the heart's electrical impulses become abnormal. These disturbances can lead to various symptoms, depending on their severity and the underlying cause. Some common factors contributing to arrhythmias include hypoxia, ischemia, electrolyte imbalances, excessive catecholamine exposure, drug toxicity, and muscle overstretching. Arrhythmias can be classified into two main types based on the rate and site of origin of abnormal heart rhythms.
892
Alterations in Respiration II
827
There are numerous types of normal and abnormal respiration. Based on ventilatory movements, breathing patterns are classified as regular, deep, or shallow. Examples include Biot's breathing, Cheyne-Stokes respiration, Kussmaul's breathing, hyperventilation, and hypoventilation. Each pattern is clinically significant and aids in evaluating patients.
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
827

