Related Experiment Video
Updated: Jul 10, 2026

Urinary Tract Infection in a Small Animal Model: Transurethral Catheterization of Male and Female Mice
Published on: December 1, 2017
Urine Contamination Prevalence Using a Midstream Collection Device Compared with Clean Voided Collections in Dogs
Meghan Hoel1, Faye A Hartmann2, Michael R Lasarev3
1School of Veterinary Medicine (M.H.), University of Wisconsin-Madison, Madison, Wisconsin.
A midstream urine collection device (MCD) showed no advantage over standard clean-caught (SCC) methods for reducing bacterial contamination in dogs. Both methods were less reliable than cystocentesis (CYS) for obtaining uncontaminated urine samples.
Area of Science:
- Veterinary Medicine
- Urology
- Diagnostic Microbiology
Background:
- Minimally invasive urine collection is preferred, but contamination is common.
- Urine contamination can occur from the urethra and external genitalia during voiding.
- Discarding the initial urine stream is a potential method to reduce contamination.
Purpose of the Study:
- To compare the efficacy of a midstream urine collection device (MCD) versus standard clean-caught (SCC) voided urine collection in reducing bacterial and cellular contamination in dogs.
- To evaluate the prevalence of contamination using MCD, SCC, and cystocentesis (CYS) techniques.
Main Methods:
- A descriptive cross-sectional study involving urine collection from dogs.
- Three urine collection techniques were employed: standard clean-caught (SCC), midstream collection device (MCD), and cystocentesis (CYS).
- Urinalysis and aerobic urine culture were performed, with prevalence described using percentages and confidence intervals.
Main Results:
- Positive urine culture prevalence did not differ significantly between SCC and MCD (P = .099).
- Cystocentesis (CYS) demonstrated significantly lower positive urine culture prevalence compared to both SCC (P < .001) and MCD (P = .009).
- No significant difference in other urinalysis variables was observed between SCC and MCD.
Conclusions:
- The midstream urine collection device (MCD) offers no significant advantage over the standard clean-caught (SCC) technique for reducing contamination in canine urine samples.
- Both SCC and MCD are suitable alternatives to cystocentesis (CYS) when CYS is not feasible.
- Clinicians should exercise caution when interpreting results from SCC and MCD due to a higher likelihood of bacterial contamination compared to CYS.
Related Concept Videos
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Urine Studies I: Urinalysis
Imaging Studies VI: Voiding Cystourethrography and Cystography
Urodynamic Studies: Uroflowmetry
Urine Studies II: Urine Culture and Sensitivity Test
Microbiota of the Urogenital Tract