A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Parameter Selection for Convex Optimization Time Calibration for a 2-Panel PET System
Gregory Romanchek1,2, Shiva Abbaszadeh2
1Dept. of Nuclear, Plasma, and Radiological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61891, USA.
Abstract:
Coincidence timing calibration is fundamental to PET imaging. The electronics, cable lengths, and detector physics such as charge drift and depth dependence add to the measured time differences in coincidence sorting - increasing random rate, decreasing true rate, and degrading system performance. This work investigates the parameter selection for convex optimization (Ordinary Least Squares) for timing calibration. We test the correlation between commonly selected parameters and the experimentally measured coincidence time difference. Additionally, we test 127 nested models of a parameterized regression equation to identify the those which optimize MSE, BIC, and FWHM, respectively. In each of these models, the FWHM performance improved ~53%, though the value shifted from ~ 304 to 160 ns - far from ~ 10 ns FWHM CZT can achieve. The results point to the lack of a necessary parameter, such as trigger threshold level or temperature, or data which is too variable for the OLS optimization.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses