Related Experiment Video
Updated: Jun 11, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Significance of the local largest bipolar voltage for the optimized ablation strategy using very high-power short
Masateru Takigawa1, Shinsuke Miyazaki1, Tasuku Yamamoto1
1Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, 113-8510, Tokyo, Japan.
Purpose:
Very high-power short-duration (vHPSD) ablation creates shallower lesions, potentially reducing efficacy. This study aims to identify factors leading to insufficient lesions during pulmonary vein antral isolation (PVAI) with vHPSD-ablation and to develop an optimized PVAI strategy using this technology.
Methods:
PVAI was performed on 41 atrial fibrillation patients using vHPSD-ablation (90 W/4 s). Lesion parameters were recorded and analyzed to identify predictors of insufficient lesions. An optimized PVAI strategy, based on these predictors, was tested in subsequent 42 patients.
Results:
In total, 3099 RF-applications, including 103(3.3%) insufficient lesions, were analyzed. First-pass PVAI was achieved in 19/40(47.5%) right PVs and 24/41(58.5%) left PVs. Multivariate analysis identified significant predictors of insufficient lesions: local largest bipolar voltage (Bi-V), average contact force, baseline impedance, impedance drop, temperature rise, inter-lesion distance (ILD), and anatomical location (carina or not). An ILD:4-6 mm increased the risk of insufficient lesions 2.2-fold, and lesions at the carina increased it 3.6-fold for both ILD < 4 mm and ILD:4-6 mm. Local largest Bi-V was the strongest predictor for insufficient lesions. The optimized PVAI approach, utilizing vHPSD-ablation with an ILD < 4 mm in non-carinal areas with Bi-V < 4 mV, and high-power ablation-index guided ablation (HPAI, 50 W, ablation-index:450-550) in remaining areas, achieved first-pass PVAI in 92.7% of right PVs and 88.1% of left PVs, using vHPSD-ablation in approximately 65% of total RF-applications. The optimized PVAI achieved significantly higher first-pass PVI rate (p < .0001) with shorter ablation time (p = .04).
Conclusion:
Appropriate use of vHPSD and HPAI, based on local largest Bi-V and anatomical information, may achieve high first-pass PVAI rates in shorter ablation time with minimal energy delivery.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Maximum Power Transfer
By substituting the entire circuit with...
The Maximum Power Transfer Theorem
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
Voltage Doubler Circuit
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no current...
Maximum Power Flow and Line Loadability
Absolute and Local Extreme Values