Related Experiment Video
Updated: Jun 8, 2025

Experimental Model of Ligature-Induced Peri-Implantitis in Mice
Published on: May 17, 2024
Clinical and Radiographic Features of Peri-Implant Medication-Related Osteonecrosis of the Jaw: A Retrospective Study
Hyeon-Gyu Jo1, Wonse Park2, In-Ho Cha1
1Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Seoul, South Korea.
Introduction:
This study aimed to analyze the factors affecting the occurrence of peri-implant medication-related osteonecrosis of the jaw (PI-MRONJ) in patients using anti-resorptive drugs (ARDs) on different implant position, inclinations, and types of prosthesis.
Methods:
The data of 75 patients with bone necrosis that progressed around the implant between 2018 and 2022 were retrospectively examined to identify the factors influencing PI-MRONJ. Data, including patient demographics (age, sex, smoking status, concomitant disease, time of ARD therapy, dose of ARDs, and parafunctional habits) and implant-specific information (type of prosthesis, angle of insertion), were extracted from medical and dental records.
Results:
Tilted implants with an angle ≥ 5.1° relative to the occlusal plane of the prosthesis had a stronger association with PI-MRONJ in comparison to non-tilted implants (inclination was < 5°). Additionally, the boundary of the area of osteonecrosis around the fixture was larger for the splinted implant-supported crowns than for the single implant supported crowns).
Conclusion:
In patients taking anti-resorptive medications the inclination of the implant was associated with the occurrence of PI-MRONJ. Further studies are required to confirm the clinical findings.