Published on: May 5, 2022
Identification of heart rate dynamics during treadmill and cycle ergometer exercise: the role of model zeros and dead
1rehaLab - the Laboratory for Rehabilitation Engineering ,Institute for Human Centred Engineering HuCE School of Engineering and Computer Science, Bern University of Applied Sciences,, Biel/Bienne, 2501, Switzerland.
Background:
The response of heart rate to changes in exercise intensity is comprised of several dynamic modes with differing magnitudes and temporal characteristics. Investigations of empirical identification of dynamic models of heart rate showed that second-order models gave substantially and significantly better model fidelity compared to the first order case. In the present work, we aimed to reanalyse data from previous studies to more closely consider the effect of including a zero and a pure delay in the model.
Methods:
This is a retrospective analysis of 22 treadmill (TM) and 54 cycle ergometer (CE) data sets from a total of 38 healthy participants. A linear, time-invariant plant model structure with up to two poles, a zero and a dead time is considered. Empirical estimation of the free parameters was performed using least-squares optimisation. The primary outcome measure is model fit, which is a normalised root-mean-square model error.
Results:
A model comprising parallel connection of two first-order transfer functions, one with a dead time and one without, was found to give the highest fit (56.7 % for TM, 54.3 % for CE), whereby the non-delayed component appeared to merely capture initial transients in the data and the part with dead time likely represented the true dynamic response of heart rate to the excitation. In comparison, a simple first-order model without dead time gave substantially lower fit than the parallel model (50.2 % for TM, 47.9 % for CE).
Conclusions:
This preliminary analysis points to a linear first-order system with dead time as being an appropriate model for heart rate response to exercise using treadmill and cycle ergometer modalities. In order to avoid biased estimates, it is vitally important that, prior to parameter estimation and validation, careful attention is paid to data preprocessing in order to eliminate transients and trends.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...