Related Experiment Video
Updated: Jun 7, 2025

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Triple acquisition mass spectrometry (TRAM) combining targeted and non-targeted metabolomics in a single run
Lisa Panzenboeck1, Harald Schoeny2, Bruno Stelzer2
1Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Str. 38, 1090, Vienna, Austria; Vienna Doctoral School in Chemistry (DoSChem), University of Vienna, Waehringer Str. 42, 1090, Vienna, Austria.
Background:
We introduce TRAM, a triple acquisition strategy on a high-speed quadrupole time-of-flight mass spectrometer for merging non-targeted and targeted metabolomics into one run. TRAM stands for "quasi-simultaneous" acquisition of (1) a full scan MS1, (2) top 30 data-dependent MS2 (DDA), and (3) targeted scheduled MS2 for multiple reaction monitoring (MRM) within measurement cycles of ∼1 s. TRAM combines the selectivity and sensitivity of state-of-the-art targeted MRM-based methods with the full scope of non-targeted analysis enabled by high-resolution mass spectrometry.
Results:
In this work, we deploy a workflow based on hydrophilic interaction liquid chromatography (HILIC). For a broad panel of metabolites, we provide chromatographic retention times, and optimized conditions as a basis for targeted MRM experiments, listing accurate masses and sum formulas for fragment ions (including fully 13C labeled analogs). Validation experiments showed that TRAM offered (1) linear working ranges and limits of quantification comparable to MRM-only methods, (2) enabled accurate quantification in SRM 1950 human plasma reference material, and (3) was equivalent to DDA-only approaches in non-targeted metabolomics. Metabolomics in human cerebrospinal fluid showcased the power of the strategy, emphasizing the need for high coverage/high throughput metabolomics in clinical studies.
Significance:
Acquiring up to 30 data-dependent spectra per MS cycle while still offering gold standard absolute quantification down to low nanomolar concentrations, TRAM allows in-depth profiling and reduces required sample volume, time, cost, and environmental impact.
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Analyzers: Common Types
Mass Spectrometers
Mass Spectrometry: Overview

