Computerized Adaptive Testing System of Functional Assessment of Stroke
Published on: January 7, 2019
Validity and reliability of the functional test for hemiplegic upper Extremity-Thai version
Pisak Chinchai1, Pheangrawee Pingmuang2, Krongporn Chinchai1
1Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
Background:
There are very few standard instruments currently available for measuring upper extremity (UE) functions for patients with stroke in Thailand.
Objectives:
This study aims to examine the concurrent validity, construct validity, and stability reliability of the Functional Test for Hemiplegic Upper Extremity (FTHUE)-Thai version for patients with stroke.
Methods:
Thirty hemiplegic participants from five community rehabilitation centers in Chiang Mai province and 30 healthy subjects were recruited. The FTHUE-Thai version and the Fugl-Meyer Assessment for the Upper Extremity (FMA-UE) were the instruments used. Concurrent validity was determined by investigating the relationship between the FTHUE-Thai version and the FMA-UE. Construct validity was investigated by comparing the performance of FTHUE-Thai version between stroke participants and healthy subjects. The stability reliability of the FTHUE-Thai version, which measured the UE function of stroke participants twice in a two-week's period, was also investigated. The statistics used were Spearman's correlation coefficient and the Mann-Whitney test.
Results:
There were significant correlations between the UE function, as measured by the FTHUE-Thai version, and the arm, and hand sub-scores, as well as the total scores of the FMA-UE (r = 0.93, r = 0.84, and r = 0.95, respectively), indicating good concurrent validity. Stability reliability was also good (r = 0.98, weighted kappa = 0.94). A known group technique test revealed significantly different scores between stroke patients and healthy subjects (p < .001), indicating good construct validity.
Conclusion:
The FTHUE-Thai version could be a reliable measurement tool for the UE function in stroke patients in the Thai context.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
05:28Author Spotlight: Enhancing Upper Limb Rehabilitation in Stroke Patients Through Advanced Robotic and Neuromodulation Technologies
Published on: October 11, 2024
Related Concept Videos
Reliability and Validity
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Non-destructive Tests for Concrete Strength