Related Experiment Video
Updated: Jun 7, 2025

A Filter-based Surface Enhanced Raman Spectroscopic Assay for Rapid Detection of Chemical Contaminants
Published on: February 19, 2016
Direct detection of melamine in milk via surface-enhanced Raman scattering using gold-silver anisotropic
Mohamed Shameer1, Kabali Vijai Anand2, Javad B M Parambath3
1Center for Advanced Materials Research, Research Institute of Sciences and Engineering, University of Sharjah, PO Box 27272, Sharjah, United Arab Emirates; Department of Physics, Sathyabama Institute of Science & Technology, Chennai 600 119, Tamil Nadu, India.
Abstract:
As the degree of anisotropy in nanoparticle morphology increases, the resulting electromagnetic enhancement can be significantly intensified. Herein, we have attempted to develop anisotropic gold-silver (a-AuAg) nanoparticles deposited on a titanium sheet (a-AuAg@Ti) as a highly efficient Surface-enhanced Raman Spectroscopy (SERS) sensor for rapid detection of health-hazardous milk adulterants like melamine. Hierarchical a-AuAg nanoparticles have been synthesized via a facile seed and growth-mediated method, followed by immobilization on a titanium sheet using a drop-casting technique. The structural, morphological, chemical, and optical properties of a-AuAg@Ti sensors have been systematically investigated and correlated with their respective SERS performance. Morphological analysis revealed the occurrence of triangular, hexagonal, and pentagonal-shaped nanoparticles with an average particle size of ∼ 23 to 26 nm. Preliminary SERS analysis using Rhodamine 6G (R6G) probe molecule revealed significantly higher SERS activity for a-AuAg nanoparticles compared to their spherical counterparts. This could be attributed to the lightning rod effect associated with the synthesized anisotropic nanostructures. An enhancement factor of 1.7 x 108 has been estimated for a-AuAg@Ti sensor with excellent signal reproducibility. Further, the efficacy of melamine detection has been investigated by spiking it into water and milk samples. The estimated lower detection limit (LDL) near picomolar and nanomolar concentrations have been obtained for melamine-spiked samples in water and milk, respectively. High-performance liquid chromatography analysis for melamine revealed an LDL of only 0.1 µM, indicating the higher sensitivity of a-AuAg@Ti SERS sensor. Moreover, we have also analyzed commercial milk products to verify the melamine contents, but none of them showed melamine-specific fingerprint bands. Our findings highlight the superior sensitivity of a-AuAg@Ti substrates for real-time melamine detection, making them excellent optical sensing tools for food safety analysis.