Symmetric versus asymmetric tibial components: A systematic review of comparative studies
Bassem I Haddad1, Alaa Tarazi2, Raha Alzoubi3
1Department of Special Surgery, Division of Orthopedics, School of Medicine, The University of Jordan, Amman, Jordan.
Background:
Total knee arthroplasty (TKA) is a widely performed procedure that significantly enhances patients' quality of life by reducing pain and improving daily function. While the traditional tibial plate design used in TKA has been symmetrical, there has been a recent trend towards using asymmetrical designs. Our study aimed to compare symmetrical and asymmetrical tibial designs, focusing on outcomes related to overhang, malrotation, and tibial coverage.
Methods:
This systematic review was conducted in accordance with PRISMA guidelines. A comprehensive search of PubMed, Scopus, Web of Science, and Cochrane databases was carried out up to January 22nd, 2024, to identify comparative studies on symmetrical and asymmetrical designs, as well as those reporting postoperative functional and clinical outcomes. The risk of bias in the included studies was evaluated using the Newcastle-Ottawa Scale (NOS).
Results:
This systematic review included 587 patients from seven comparative studies that met the inclusion criteria. Our findings indicate that asymmetrical tibial components generally provided better outcomes in terms of tibial coverage, malrotation, and overhang. Asymmetrical designs provided greater tibial coverage and reduced posterolateral overhang compared to symmetrical designs, which is essential for minimizing complications like soft tissue irritation and patellar maltracking. Additionally, asymmetrical components were associated with less severe tibial malrotation.
Conclusion:
This systematic review showed that asymmetrical tibial implants offer better tibial coverage, with less overhang and fewer rotational issues compared to symmetrical implants. As a result, asymmetrical designs in TKA may lower complication rates, enhance patient satisfaction, and improve quality of life post-surgery.
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Equivalent Couples
Two couples are considered to be equivalent if they produce the same rotational effect on a rigid body. In other words, the two couples have the same magnitude and act in the same direction, causing the same angular displacement or acceleration in the body.
For instance, consider two couples lying in the plane of the page, with one having a pair of equal...
Quality Assurance
Classification of Systems-I
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...