Related Experiment Video
Updated: Jun 7, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Comparison of 3-month clinical outcomes between two enhanced monofocal intraocular lenses: A single-center
Vito Spagnuolo1,2, Giulio Vicini1,3, Ginevra Marincolo1,2
1Eye Clinic, Neuromuscular and Sense Organs Department, Careggi University Hospital, Florence, Italy.
Abstract:
PurposeThis study aims to compare the 3-month clinical outcomes between two enhanced monofocal intraocular lenses (IOLs) following cataract surgery.Setting: Eye Clinic of Careggi University Hospital, Florence, Italy.DesignSingle-center prospective study.MethodsWe included patients with cataract and corneal astigmatism less than 0.75 D, with no ocular comorbidities, who underwent unilateral cataract surgery with implantation of either the Tecnis Eyhance ICB00 (N = 25) or Evolux (N = 25) IOLs. Standard cataract procedures were performed without complications. The main outcome measures included uncorrected and corrected visual acuity at distance (4 m), intermediate (60 cm) and near (40 cm) at 3-month follow-up. Additionally, monocular defocus curves, aberrometric profiles, and perceptions of halo and glare were evaluated.ResultsThe study involved 50 patients (26 male, 24 female) with a mean age of 68 ± 8 years. Preoperative characteristics were similar between the groups, and no intraoperative or postoperative complications were reported. Statistically significant differences were observed between the groups, with the Evolux IOL showing superior results (p < 0.05) in terms of uncorrected and corrected visual acuity at near, intermediate, and distance, as well as in aberrometric profiles (lower-order aberration root-mean-square [RMS], higher-order aberration RMS, spherical equivalent RMS, and point spread function) and defocus curves.ConclusionsBased on our experience, while both IOLs offer substantial visual performance for intermediate and distance vision, the Evolux IOL demonstrated superior mean visual outcomes and objective parameters at the 3-month follow-up compared to the Tecnis Eyhance IOL. This indicates a potential advantage of the Evolux IOL in providing better visual performance.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment