Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Evaluation of various mass spectrometry mode based on gas chromatography for quantifying the polycyclic aromatic
Shan Bao1, Jiankun Qian2, Tian Qiu1
1China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China; National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China.
Abstract:
Hydroxyl polycyclic aromatic hydrocarbons (OH-PAHs) are frequently used as biomarkers to assess human exposure to polycyclic aromatic hydrocarbons (PAHs), which are typically present in minute concentrations in the human body. Although several studies have outlined methods for measuring OH-PAHs in human urine, these approaches may have limitations concerning the range of compounds detected, the sample volume required for pre-treatment, accuracy, and instrument maintenance costs. Advances in mass spectrometry technology have facilitated the use of various mass spectrometry modes based on gas chromatography. It is essential to evaluate different mass spectrometry modes to identify a more reliable and practical method for quantifying OH-PAHs in urine. Our comparative analysis of three gas chromatography-mass spectrometry modes revealed that advanced electron ionization (AEI) mode exhibited greater sensitivity for determination compared to electron ionization (EI) mode in tandem mass spectrometry. The method validation criteria were satisfied by GC-AEI-MS/MS, which demonstrated acceptable measurement errors (MEs) ranging from -23.0 % to 19.5 %, recoveries between 81.6 % and 112.1 %, and precision levels below 10.1 %. Furthermore, the reliability and accuracy of the GC-AEI-MS/MS method were corroborated through Intraclass Correlation Coefficient (ICC) evaluation (values > 0.75), participation in external proficiency testing programs (G-EQUAS), and analysis of certified reference materials, which exhibited a relative deviation of <6.1 %. In summary, GC-AEI-MS/MS is a robust and reliable method for analyzing urine samples and conducting large-scale human biological monitoring. It was employed to determine 16 OH-PAHs in human urine as part of the China National Human Biomonitoring Program (CNHBM).
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
09:28One-step Metabolomics: Carbohydrates, Organic and Amino Acids Quantified in a Single Procedure
Published on: June 25, 2010
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Types of Detectors
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...