Related Experiment Video
Updated: Jun 7, 2025

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Fluorescence and color adjustment potentials of paste-type and flowable resin composites in cervical restorations
Ezgi Tüter Bayraktar1, Ezgi Kızıl Öztürk2, Cevdet Can Saygılı2
1Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Türkiye. tuterezgi@gmail.com.
Objective:
Comparatively assess the fluorescence and color adjustment potentials of paste-type and flowable resin composites performed in cervical restorations.
Materials And Methods:
Five paste-type resin composites and 5 highly-filled flowable composites were investigated (n=5 for each). Class V cavities on 50 extracted A2 shade human central incisors were restored. Cross-polarization (CP) and fluorescence illumination (FI) images were recorded for each restoration. L*a*b* values were analyzed using the Photoshop software and color adjustment (ΔECP) and fluorescence adjustment (ΔEFI) levels were quantitatively assessed. Kruskal Wallis Test, Independent Samples t Test, One Way Anova-Welch test, and Pearson Correlation were used for the statistical analyses. The deemed significance was set at p<.050.
Results:
Paste-type composites presented significantly lower ΔEFI and ΔECP values than the flowable composites (p=.006 and p<.001 respectively). ΔEFI and ΔECP values were positively correlated (r=0.584; p<.001). Paste-type Gaenial A'chord presented the lowest ΔEFI value [7.67 (5.35 - 10.99)b], while Estelite Asteria presented significantly the highest [19.94 (17.08 - 22.17)c]. Charisma Diamond One Flow presented the highest ΔECP value [3.25 (3.13 - 3.39)a] and Gaenial A'chord presented the lowest [0.79 (0.48 - 0.87)e] which was the only imperceptible score (<0.8). The only clinically acceptable color adjustment was found for Geanial Universal Injectable [1.06 (0.73 - 1.62)e] among the flowable composites. ΔEFI and b* values were positively correlated (r=0.493; p<.001).
Conclusions:
Color adjustment level and fluorescence adjustment level were considered coherent for particular composite brands. At the same time, both were better for the paste-type composites than the flowable composites on A2 base shade class V restorations. Fluorescence adjustment potential as well as the color adjustment potential varied among different composite brands regarding paste-type and flowable composites.
Clinical Significance:
Understanding both the color and fluorescence adjustment potentials of paste-type and flowable resin-based composite materials is clinically vital to achieve the high-end esthetics.
Related Concept Videos
Porosity in Cement Paste
The balance of water to cement in the mix is...
Variables Affecting Phosphorescence and Fluorescence
Photoluminescence: Applications
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...

