Purpose:
The purpose of this study was to conduct a systematic review evaluating the reported complications and outcomes of bone-anchored prostheses in digit and partial hand amputees.
Methods:
A literature review of primary research articles on osseointegration and bone-anchored prostheses for digit and partial amputees was performed. The Medline, Embase, Scopus, and Cochrane Library databases were queried. Inclusion criteria were journal articles that evaluated osseointegration and bone-anchored prostheses in digit and partial hand amputees. The main outcome measures were reported complications and the need for revision surgery. Secondary outcomes included all reported outcome assessments.
Results:
Fifteen articles were included with publication dates ranging from 1996 to 2022. The sample sizes ranged from single-patient case reports to a 13-patient retrospective study. Overall, 33 men and 16 women were reported with a mean age of 33.6 years (range: 12-68) and a total of 71 amputated digits. The median follow-up was 2.1 years (IQR: 1.1-6.8 years). A total of 24 complications were reported in 14 digits (19.7%). Complications included superficial infection in 6 digits (8.5%), abutment loosening or failure in 5 (7%), fixture aseptic loosening in 4 (5.6%), deep infection in 1 (1.4%), and soft tissue instability in 1 (1.4%). Sixteen revision surgeries or component changes were reported.
Conclusions:
Bone-anchored prostheses using osseointegrated implants in the hand are associated with favorable outcomes in the limited number of low-quality studies available for review. Superficial infections and implant-related failures were the most frequently reported complications.
Type Of Study/Level Of Evidence:
Systematic review IV.