Related Experiment Video
Updated: Jun 6, 2025

Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
Replacing traditional coffee appraisers with inductively coupled plasma - mass spectrometry (ICP-MS): From manual
Xiaowei Pan1,2, Wenjing Yan2, Xiaopeng Wu3
1Agricultural Product Processing Research Institute, Chinese Academy of Tropical Agricultural Sciences, Zhanjiang, Guangdong Province 524001, China.
Abstract:
Scientific development provides opportunities to replace many traditional manual methods to achieve more accurate results and higher efficiency. To scientifically ascertain the geographical origin of coffee, this study develops a method for the rapid determination of 16 inorganic elements in coffee using microwave digestion combined with the ICP-MS internal standard method. Principal component analysis (PCA), Fisher discriminant analysis (FDA), and Partial least squares discriminant analysis (PLS-DA) are employed to analyze 40 coffee samples from three production areas of Pu'er, Baoshan, and Wanning. The results show that the linear correlation coefficients of the 16 elements in this method are above 0.999, the detection limits are in the range of 0.0004-0.63 mg/kg, the RSD of the precision experiments are 4.5 %-13.5 %, the recovery rate of the peak experiment is 86.0 %-96.3 % with the RSD of 1.1 %-8.8 %, and the results of the standard substances are within the range of standard values. Using the discriminant analysis of inorganic elements in coffee (FDA and PLS-DA), coffee origin discrimination was realized, and six key elements (Al, Mn, Fe, Cu, Na, and Ba) are identified as effective discriminatory indexes. Accordingly, a coffee origin discrimination model is established, and the overall accuracy discrimination rate of the discrimination model are all more than 90.0 %, and FDA > PLS-DA. The findings indicated that the method has good accuracy and reliability, is suitable for analyzing and determining multiple elements in sample components as targets, and may have a positive impact on the development of related industries.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
08:01Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
Published on: December 15, 2015
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...