Multivariate linear regression to predict association of non-invasive arterial stiffness with cardiovascular events

Susan Darroudi1, Mostafa Eslamiyeh2, Amin Mansoori1,3

  • 1Vascular and Endovascular Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

ESC Heart Failure
|November 25, 2024
PubMed

Insights

Pulse wave velocity (PWV) is linked to cardiovascular disease (CVD) and risk factors like diabetes, obesity, and hypertension. PWV may be a superior predictor of future CVD events in clinical practice.

Area of Science:

  • Cardiology
  • Vascular Medicine
  • Biomedical Engineering

Background:

  • Arterial stiffness is a key indicator of increased systolic blood pressure and pulse pressure.
  • It is also a predictor for the development of cardiovascular disease (CVD).

Purpose of the Study:

  • To investigate the relationship between arterial stiffness and the occurrence of future CVD events.
  • To assess the predictive value of arterial stiffness parameters for CVD.

Main Methods:

  • Utilized the SphygmoCor XCEL System to measure pulse wave velocity (PWV), central augmentation index (CAI), cardio-ankle vascular index (CAVI), and central aortic pressure (CAP).
  • Employed a multivariate multiple regression model to analyze factors associated with arterial stiffness parameters, adjusting for confounders.
  • Included 363 healthy participants, 226 with reported CVD symptoms, and 292 with a history of major cardiovascular events from the MASHAD cohort study.

Main Results:

  • Mean PWV was significantly higher in individuals with a confirmed CVD event (P < 0.001).
  • Multivariate regression revealed significant associations between PWV and CVD status, and between hypertension and obesity with PWV.
  • Diabetes showed a significant association with CAI (P < 0.05).

Conclusions:

  • Pulse wave velocity (PWV) is associated with cardiovascular disease (CVD) and its risk factors, including diabetes, obesity, and hypertension.
  • PWV may demonstrate greater efficacy than other arterial stiffness measures in predicting CVD in clinical settings.
Abstract

Related Concept Videos

Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
656
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
555
Multiple Regression01:25

Multiple Regression

Multiple regression assesses a linear relationship between one response or dependent variable and two or more independent variables. It has many practical applications.
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
2.9K
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
872