Related Experiment Video
Updated: Jun 6, 2025

Intraoperative Gastroscopy for Tumor Localization in Laparoscopic Surgery for Gastric Adenocarcinoma
Published on: August 9, 2016
Comparative Analysis of CT Fluoroscopy Modes and Gastropexy Techniques in CT-Guided Percutaneous Radiologic
Michael P Brönnimann1,2, Mauro Tarca3, Laura Segger2
1Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 10, 3010 Bern, Switzerland.
Background/Objectives:
This study was conducted to compare two modes of computed tomography fluoroscopy (CTF) and two gastropexy techniques used in CT-guided percutaneous radiologic gastrostomy (CT-PRG) aiming to identify the optimal techniques for image guidance and gastropexy and, thus, to overcome the current lack of consensus on the preferred modalities.
Methods:
We retrospectively identified 186 successful CT-PRG procedures conducted evenly across two university hospitals from January 2019 to December 2023. Patients were divided into two groups (intermittent multislice CT biopsy mode-guided technique (MS-CT BM) and retention anchor suture (T-fastener) versus real-time (RT-)CTF and gastropexy device) for descriptive analysis of demographics, indication for PRG, radiation exposure (DLP), procedural time, number of CT scans, gastropexy time, and complications. Differences were assessed for statistical significance using Fisher's exact test and the Mann-Whitney U-test.
Results:
Our final study population comprised 100 patients (50 from each center; 62.52 ± 12.36 years, 73 men). There was a significant difference in radiation exposure between MS-CT BM (group 1) and RT-CTF (group 2), with an average dose-length product (DLP) of 56.28 mGycm×m ± 67.89 and 30.91 ± 27.53 mGycm×cm, respectively (p < 0.001). PRG with RT-CTF guidance was significantly faster than PRG with MS-CT BM, with an average difference of 10.28 min (p < 0.001). No significant difference in duration was found between the two gastropexy methods compared (retention anchor suture, 11.50 ± 5.239 s vs. gastropexy device, 11.17 ± 6.015 s; p = 0.463). Complication rates did not differ significantly either (p = 0.458).
Conclusions:
Our findings indicate comparable efficacy and safety of the two gastropexy methods and underscore that the choice of CTF mode for image guidance has only a small role in reducing radiation exposure in patients undergoing CT-PRG. Instead, it is essential to avoid control scans.
More Related Videos
03:32Single Incision Plus One Port Laparoscopic Proximal Gastrectomy with Double Channel Anastomosis for Gastric Cancer Treatment
Published on: December 27, 2024
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Endoscopic Procedures V: ERCP
Patient...
Enteral Nutrition II: Nasointestinal and Gastrostomy Feeding
Nasointestinal Feeding
Nasointestinal feeding involves placing a tube...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...