In Situ Potentiometric Monitoring of Nitrate Removal from Aqueous Solution by Activated Carbon and Ion Exchange Resin
José Manuel Olmos1, Lucía Gil1, Joaquín Ángel Ortuño1
1Department of Analytical Chemistry, University of Murcia, 30100 Murcia, Spain.
Abstract:
A nitrate selective electrode was used for real-time in situ potentiometric monitoring of a batch nitrate removal process using activated carbon and ion exchange resin. A plasticized polymeric membrane consisting of polyvinyl chloride, 2-nitrophenyl octyl ether and tridodecyl methyl ammonium chloride was incorporated into an ion-selective electrode body. First, the dynamic potential response of the electrode to nitrate was investigated. Two commercial activated carbons with different physical properties were then tested. Nitrate removal with these carbons was monitored potentiometrically using several nitrate concentrations. The extreme turbidity of the solutions was not a drawback during potentiometric monitoring of the process, which is a clear advantage over other methods such as optical monitoring. The potential versus time recordings were converted into nitrate concentration versus time plots, which were evaluated with different adsorption kinetic models. A pseudo-second order kinetic model for nitrate adsorption on both activated carbons was found to fit the experimental data very well. The values of the kinetic parameters were very different between the two activated carbons. The proposed methodology was also satisfactorily applied to the study of nitrate removal by an ion exchange resin. In this case, the experimental results clearly follow a pseudo-first order kinetic model. Potential applications of the proposed methodology for monitoring nitrate removal in real water samples are discussed.
More Related Videos
07:14Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
08:25Measuring Nitrite and Nitrate, Metabolites in the Nitric Oxide Pathway, in Biological Materials using the Chemiluminescence Method
Published on: December 25, 2016
Related Concept Videos
Potentiometry: Overview
Potentiometric Titration: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...