Related Experiment Video
Updated: Jun 6, 2025

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Pulsed Eddy Current Imaging of Partially Missing Solder in Brazing Joints of Stainless Steel Core Plates
Changchun Zhu1, Hanqing Chen2, Xuecheng Zhu1
1School of Mechanical Engineering and Mechanics, Xiangtan University, Xiangtan 411105, China.
Abstract:
Stainless steel core plates (SSCPs) show great potential for modular construction due to their superiority of excellent mechanical properties, light weight, and low cost over traditional concrete and honeycomb structures. During the brazing process of SSCP joints which connect the skin panel and core tubes, it is difficult to keep an even heat flow of inert gas in the vast furnace, which can lead to partially missing solder defects in brazing joints. Pulsed eddy current imaging (PECI) has demonstrated feasibility for detecting missing solder defects, but various factors including lift-off variation and image blurring can deteriorate the quality of C-scan images, resulting in inaccurate evaluation of the actual state of the brazed joints. In this study, a differential pulsed eddy current testing (PECT) probe is designed to reduce the lift-off noise of PECT signals, and a mask-based image segmentation and thinning method is proposed to eliminate the blurring effect of C-scan images. The structure of the designed probe was optimized based on finite element simulation and the positive peak of the PECT signal was selected as the signal feature. Experiments with the aid of a scanning device are then carried out to image the interrogated regions of the SSCP specimen. The peak values of the signals were collected in a matrix to generate images of the scanned brazing joints. Results show that lift-off noise is significantly reduced by using the differential probe. Image blurring caused by the convolution effect of the probe's point spread function with the imaging object was eliminated using a mask-based image segmentation and thinning method. The restored C-scan images enhance the sharpness of the profiles of the brazing joints and the opening in the images accurately reflect the missing solder of the brazed joints.
More Related Videos
Related Concept Videos
Eddy Currents
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Metal-Semiconductor Junctions
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The...
Electrodeposition
Electrodeposition can...
Magnetic Field Of A Current Loop
Biasing of Metal-Semiconductor Junctions
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...

