Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

337
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
337
IR Spectrometers01:25

IR Spectrometers

1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reply to "Comment on Liu et al. 'Discrepancies of Measured SAR between Traditional and Fast Measuring Systems' <i>Int. J. Environ. Res. Public Health</i>, 2020, <i>17</i>, 2111".

International journal of environmental research and public health·2020
Same author

Discrepancies of Measured SAR between Traditional and Fast Measuring Systems.

International journal of environmental research and public health·2020
Same author

A clinical evaluation of amlexanox oral adhesive pellicles in the treatment of recurrent aphthous stomatitis and comparison with amlexanox oral tablets: a randomized, placebo controlled, blinded, multicenter clinical trial.

Trials·2009
Same author

Long-term assessment of bladder and bowel dysfunction after radical hysterectomy.

Gynecologic oncology·2009
Same author

Oxidative stress contributes to silica nanoparticle-induced cytotoxicity in human embryonic kidney cells.

Toxicology in vitro : an international journal published in association with BIBRA·2009
Same author

A rapid and simple method for identifying Mycobacterium tuberculosis W-Beijing strains based on detection of a unique mutation in Rv0927c by PCR-SSCP.

Microbes and infection·2009
Same journal

RETRACTED: Zhang et al. A Novel Framework for Reconstruction and Imaging of Target Scattering Centers via Wide-Angle Incidence in Radar Networks. <i>Sensors</i> 2025, <i>25</i>, 6802.

Sensors (Basel, Switzerland)·2026
Same journal

Enhancing Unsupervised Multi-Source Domain Adaptation for Person Re-Identification via Mixture of Experts and Graph-Based Relation.

Sensors (Basel, Switzerland)·2026
Same journal

Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers.

Sensors (Basel, Switzerland)·2026
Same journal

Development and Experimental Validation of an Autonomous IoT-Based Monitoring System for Real-Time Water Quality Assessment in the Amazon River.

Sensors (Basel, Switzerland)·2026
Same journal

Semi-Supervised Adversarial Learning Framework for Controller Area Network Bus Intrusion Detection.

Sensors (Basel, Switzerland)·2026
Same journal

Smart Optimization Method for Safety Signs in Innovative Manufacturing Environments Integrating Industrial Field IoT Sensors and Knowledge Graphs.

Sensors (Basel, Switzerland)·2026
See all related articles

Related Experiment Video

Updated: Jun 6, 2025

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

9.6K

Multi-Frequency Microwave Sensing System with Frequency Selection Method for Pulverized Coal Concentration.

Haoyu Tian1, Feng Gao1, Yuwei Meng1

  • 1Zhejiang Energy Digital Technology Co., Ltd., Hangzhou 310012, China.

Sensors (Basel, Switzerland)
|November 27, 2024
PubMed
Summary
This summary is machine-generated.

This study introduces a novel multi-frequency microwave sensing system for accurate pulverized coal concentration (PCC) measurement. The system uses principal component analysis (PCA) and orthogonal matching pursuit (OMP) for optimal frequency selection, improving efficiency and safety in coal-fired power plants.

Keywords:
frequency selectionmicrowave sensororthogonal matching pursuit (OMP)principal component analysis (PCA)pulverized coal concentrationswitch matrix

More Related Videos

Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis
10:44

Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis

Published on: February 12, 2019

9.9K
Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow
10:34

Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow

Published on: April 24, 2014

10.7K

Related Experiment Videos

Last Updated: Jun 6, 2025

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

9.6K
Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis
10:44

Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis

Published on: February 12, 2019

9.9K
Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow
10:34

Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow

Published on: April 24, 2014

10.7K

Area of Science:

  • Engineering
  • Physics
  • Materials Science

Background:

  • Accurate pulverized coal concentration (PCC) measurement is vital for coal-fired power plant efficiency and safety.
  • Traditional single-frequency microwave methods have limitations due to frequency-dependent signal sensitivity.

Purpose of the Study:

  • To develop an innovative multi-frequency microwave sensing system for precise PCC measurement.
  • To overcome the limitations of single-frequency analysis by utilizing frequency domain information.

Main Methods:

  • Implemented a multi-frequency microwave sensing system with controlled frequencies and signal paths.
  • Applied Principal Component Analysis (PCA) for dimensionality reduction of insertion loss data.
  • Utilized Orthogonal Matching Pursuit (OMP) algorithm for optimal frequency selection based on eigenvector contributions.

Main Results:

  • The system effectively extracted features from high-dimensional PCC data and selected optimal frequencies.
  • Field experiments demonstrated a minimum Mean Absolute Error (MAE) of 1.41% and a correlation coefficient of 0.85 for PCC prediction (0-0.5 kg/kg).

Conclusions:

  • The multi-frequency microwave sensing system provides accurate and reliable quantitative PCC prediction.
  • The system enables prompt detection of PCC fluctuations, enhancing operational safety and efficiency in coal-fired power plants.