Therapeutic Monoclonal AntibodyAntidrug Antibody Affinity Constant Determination Using Capillary

Tessa Reinert1,2, Pascal Houzé2,3, Nathalie Mignet2

  • 1Laboratoire de Spectrométrie de Masse des Interactions et des Systèmes (LSMIS), Université de Strasbourg, CNRS UMR7140, CMC, Strasbourg 67081, France.

Analytical Chemistry
|November 27, 2024
PubMed

Monoclonal antibody (mAbs) therapeutics cannot evade the occurrence of adverse effects. Thus, mAbs are commonly triggering immune responses corresponding to the expression of antidrug antibodies. Antidrug antibodies can neutralize mAbs, leading to their inhibition and hasten clearance, which dramatically hampers their therapeutic effects. Therefore, studies concerning the affinity between a mAbs and the corresponding antidrug antibody are demonstrating a growing interest to further understand the outcome of biotherapeutics after administration. We describe a novel analytical approach for the determination of the dissociation constant (Kd) between a mAb and an antidrug antibody using capillary electrophoresis coupled to mass spectrometry (CE-MS/MS). The CE-MS/MS method employs a competitive assay, followed by the quantification of the residual amount of the active mAbs. The methodology allowed for the measurement of Kd using serum samples without the implementation of immobilization to achieve protein-protein interaction. This characteristic enabled us to generate the interaction in conditions reflecting the physiological environment. A mathematical treatment was developed to calculate Kd from MS/MS data, taking into account the stoichiometry of the mAbs/antidrug antibody complex and the bivalent properties of the two immunoglobulins. Prior to CE-MS/MS analysis, the interaction of the two proteins was studied by using mass photometry (MP) to determine equilibrium conditions and complexation stoichiometry. CE-MS/MS was used to investigate the interaction between infliximab and a neutralizing anti-infliximab antibody. Results allowed to measure a Kd of 14.4 ± 2.9 nM. MS instrumentation sensitivity and specificity showed to be relevant to achieve accurate and robust Kd measurements for strong interactions in the nanomolar range.

Related Concept Videos

Affinity Chromatography01:03

Affinity Chromatography

Affinity chromatography is a powerful technique extensively utilized for separating and purifying specific biomolecules from complex mixtures. It capitalizes on the highly selective binding between an analyte and its counterpart, such as antibody-antigen interactions. The counterpart is immobilized on the stationary phase, forming an affinity column. The stationary phase typically consists of solid support, such as agarose or porous glass beads, immobilizing the affinity ligand. The mobile...
543
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
6.4K
Protein-Drug Binding: Determination Methods01:22

Protein-Drug Binding: Determination Methods

Determining protein-drug binding can be achieved through indirect and direct methods, each providing valuable insights into the interaction between proteins and drugs.
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
132