Phase Contrast and Differential Interference Contrast DIC Microscopy
Published on: August 6, 2008
Differential phase contrast intensity diffraction tomography
Abstract:
Intensity diffraction tomography (IDT) is a label-free computational microscopy technique that infers 3D refractive index (RI) and absorption distributions of objects from intensity-only measurements. Nevertheless, the inherent coherent image formation model requires sequential intensity measurements under various plane wave illuminations, resulting in time-consuming data acquisition and low imaging speed. In this Letter, we propose differential phase contrast intensity diffraction tomography (DPC-IDT), which leverages partially coherent illumination to extend the accessible spectrum range, thereby achieving high-speed, motion-free 3D tomographic microscopy. DPC-IDT integrates DPC illumination within the IDT framework, allowing 3D RI tomogram reconstruction from only four intensity images under matched asymmetric annular illumination. The effectiveness of DPC-IDT is experimentally validated by RI measurements of standard microspheres. We also demonstrate dynamic 3D imaging results of living PLC cells at a 25 Hz volume rate, highlighting its potential for high-speed biological imaging of unstained samples.
More Related Videos
14:09Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
Published on: April 7, 2014
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Three-Dimensional Microscopy in Microbiology
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...