Abstract:
Attenuation correction of PET data is commonly conducted through the utilization of a secondary imaging technique to produce attenuation maps. The customary approach to attenuation correction, which entails the employment of CT images, necessitates energy conversion. However, the present study introduces a novel deep learning-based method that obviates the requirement for CT images and energy conversion. This study employs a residual Pix2Pix network to generate attenuation-corrected PET images using the 4033 2D PET images of 37 healthy adult brains for train and test. The model, implemented in TensorFlow and Keras, was evaluated by comparing image similarity, intensity correlation, and distribution against CT-AC images using metrics such as PSNR and SSIM for image similarity, while a 2D histogram plotted pixel intensities. Differences in standardized uptake values (SUV) demonstrated the model's efficiency compared to the CTAC method. The residual Pix2Pix demonstrated strong agreement with the CT-based attenuation correction, the proposed network yielding MAE, MSE, PSNR, and MS-SSIM values of 3 × 10-3, 2 × 10-4, 38.859, and 0.99, respectively. The residual Pix2Pix model's results showed a negligible mean SUV difference of 8 × 10-4(P-value = 0.10), indicating its accuracy in PET image correction. The residual Pix2Pix model exhibits high precision with a strong correlation coefficient of R2 = 0.99 to CT-based methods. The findings indicate that this approach surpasses the conventional method in terms of precision and efficacy. The proposed residual Pix2Pix framework enables accurate and feasible attenuation correction of brain F-FDG PET without CT. However, clinical trials are required to evaluate its clinical performance. The PET images reconstructed by the framework have low errors compared to the accepted test reliability of PET/CT, indicating high quantitative similarity.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...