Cardiovascular, perceptual, and performance responses to single- vs. multi-chambered blood flow restriction cuffs
Nicholas Rolnick1,2,3, Victor S de Queiros4, Masoud Moghaddam5
1Department of Exercise Science and Recreation, CUNY Lehman College, New York, NY, United States.
Introduction:
This study aimed to investigate the impact of the blood flow restriction bladder type (single- [SC-BFR] vs. multi-chambered [MC-BFR]) on exercise performance, cardiovascular responses, and perceptual experiences with exercise sessions incorporating multiple sets to volitional failure in a randomized, crossover experimental design.
Methods:
Twenty-seven healthy, physically active participants (age: 22.6 ± 5.7; weight: 74.3 ± 15.8 kg; height: 171.7 ± 7.7 cm; BMI: 25.0 ± 4.1 kg/m2; ∼93% reported regular resistance training within 6 months; 11 females) randomly performed exercise to failure (4× sets to failure, 20% 1RM, 1 min rest between sets) in each of three conditions: SC-BFR (using the Delfi Personalized Tourniquet Device inflated to 60% limb occlusion pressure), MC-BFR (using the B Strong Cuffs inflated to 300 mmHg according to manufacturer recommendations), and N-BFR (no BFR control).
Results:
SC-BFR blunted post-exercise increases in carotid-femoral pulse wave velocity (p = 0.328) (+3.3%) whereas the other conditions showed elevations (MC-BFR +11.8% [p = 0.041], N-BFR +9.3% [p = 0.012]). Discomfort was lower in N-BFR compared to SC-BFR (p < 0.001) and MC-BFR (p = 0.035) but all displayed similar exertion (p = 0.176). Median total repetitions achieved were significantly less in SC-BFR (57 [25-75th percentile: 47-65) than MC-BFR (76 [63-91] (p = 0.043) and N-BFR [106 (97-148)] p = 0.005). Per set repetition volumes were similar on set 1 between SC-BFR (p < 0.001) and MC-BFR (p = 0.001) and were lower than N-BFR (p ≤ 0.001) whereas in sets 2-4, MC-BFR performed similar number of repetitions as N-BFR (p = 0.984-1.000).
Conclusion:
Bladder design of a BFR cuff has an impact on the acute responses to exercise if applied according to recommended application guidelines, as SC-BFR impacts performance to a greater degree and mitigates post-exercise arterial stiffness responses compared to MC-BFR and N-BFR while both BFR conditions display greater levels of discomfort compared to N-BFR.
Clinical Trial Registration:
NCT06276673.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure