StressFit: a hybrid wearable physicochemical sensor suite for simultaneously measuring electromyogram and sweat
Nafize Ishtiaque Hossain1,2, Tanzila Noushin3,2, Shawana Tabassum4
1Tufts University, Medford, MA, 02155, USA.
Abstract:
This study introduces StressFit, a novel hybrid wearable sensor system designed to simultaneously monitor electromyogram (EMG) signals and sweat cortisol levels. Our approach involves the development of a noninvasive skin patch capable of monitoring skin temperature, sweat pH, cortisol levels, and corresponding EMG signals using a combination of physical and electrochemical sensors integrated with EMG electrodes. StressFit was optimized by enhancing sensor output and mechanical resilience for practical application on curved body surfaces, ensuring accurate acquisition of cortisol, pH, body temperature, and EMG data without sensor interference. In addition, we integrated an onboard data processing unit with Internet of Things (IoT) capabilities for real-time acquisition, processing, and wireless transmission of sensor measurements. Sweat cortisol and EMG signals were measured during cycling exercises to evaluate the sensor suite's performance. Our results demonstrate an increase in sweat cortisol levels and decrease in the EMG signal's power spectral density following exercise. These findings suggest that combining sweat cortisol levels with EMG signals in real-time could serve as valuable indicators for stress assessment and early detection of abnormal physiological changes.
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...