Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Features of gas chromatographic analysis of thermally unstable compounds
Igor G Zenkevich1, Tatiana A Kornilova1
1St. Petersburg State University, Institute for Chemistry, Universitetskii ave., 26, St. Petersburg 198504, Russia.
Abstract:
Confirming the stability of analytes during gas chromatographic (GC) analysis is an important criterion, especially for previously uncharacterized compounds. However, the variations of absolute peak areas at different injector temperatures usually do not allow us to reveal the thermal instability of analytes during GC analysis. Such variations may be caused by peak area known discrimination typical for using capillary columns, especially at low split injection. The thermal instability can be revealed only when using relative peak areas. The dependences of the relative peak areas of unstable analytes on the injector temperature (descending), as well as similar dependences for products of their decomposition (ascending), are characterized by the existence of two limits. Low-temperature limits correspond to the initial quantities of unstable analytes, and high-temperature limits, to their complete transformations. Such dependences can be approximated with an equation of logistic regression (synonymous: sigmoid or Boltzmann approximation). The relationships and features of gas chromatographic analysis of thermally unstable compounds are considered with products of free-radical isopropylbenzene (cumene) chlorination and with solutions of ethyl diazoacetate in different solvents as examples. The major cumene chlorination product, (1-chloro-1-methylethyl)benzene, undergoes dehydrochlorination at injector temperatures above 200 °С to form a single product, α-methylstyrene. The analysis of the ethyl diazoacetate solutions is accompanied by the formation of ethyl alkoxyacetates, products of the insertion of intermediate ethoxycarbonylcarbene into OH bonds of alcohols, if they are used as solvents. Comparing the temperatures of half-conversion of the initial ester, T(50 %), and half-formation of the products shows that they are equal to each other. This confirms both the process mechanism and the correctness of the data approximation.
More Related Videos
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...