A Quantitative Diagnostic Method Using 99mTc-pyrophosphate Lateral Planar Images to Distinguish Between Transthyretin
Junko Hara1, Shiro Ishii1, Honami Kobiyama1
1Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan.
Abstract:
Background: This study investigated the feasibility of using a quantitative diagnostic method based on 99mTc-pyrophosphate scintigraphy (PYP) lateral planar images to differentiate between PYP-positive (myocardial uptake) and false-positive (blood pool uptake) scans. Methods: The study included 93 consecutive patients with suspected transthyretin amyloid cardiomyopathy (ATTR-CM) who underwent PYP between April 2022 and December 2023. Patients were categorized using planar anterior PYP images according to the Perugini visual grading system; patients with grades ≥ 2 were analyzed. Whether the uptake of the ventricle was in the blood pool or the myocardium was confirmed by transaxial single-photon emission tomography (SPECT). The heart-to-mediastinum ratios (H/M ratio) of the left lateral planar images at 1- and 3-h were calculated by placing a circular region of interest in the heart and cephalodorsal side of the heart to determine optimal cut-off values. Results: Among the PYP images, the study analyzed 15 positives diagnosed as ATTR-CM and 10 false positives. Significant differences were observed in the H/M ratio at 1- and 3-h (both p<0.01), with 100% sensitivity and specificity using cut-off values of 1.22 and 1.21 at 1- and 3-h, respectively. The interclass correlation coefficients (2, 1) between the two readers were 0.919 and 0.958 for the 1- and 3-h H/M ratios, respectively. Conclusions: Lateral planar PYP imaging can exclude PYP false-positive cases caused by blood pools in a simple and quantitative manner using only a 1-h planar image, possibly obviating the need for SPECT imaging.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...