Extensor Carpi Radialis Brevis Tendon Rupture Following Delayed Fixation of Distal Radius Fracture: A Case Report
Liam Ortega1, Logan M Druessel, Jae Yim
1Department of Orthopaedics and Sports Medicine, Mercy Health St. Vincent Medical Center, Toledo, Ohio.
Case:
A 58-year-old woman underwent delayed fixation of an unstable distal radius fracture. At staged hardware removal, an isolated rupture of extensor carpi radialis brevis (ECRB) was discovered and tenodesed to extensor carpi radialis longus acutely. The surgical intervention allowed her to return to gardening at 2 weeks after the hardware removal with preserved function and pain control at 13-month follow-up, respectively.
Conclusion:
We present a rare complication of isolated abrasive ECRB rupture with an intra-articular distal radius fracture treated with a late decision for surgery. Our surgical intervention resolved the patient's pain and preserved function in this case.
More Related Videos
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...