Related Experiment Video
Updated: Jun 5, 2025

11:31
Antigens Protected Functional Red Blood Cells By The Membrane Grafting Of Compact Hyperbranched Polyglycerols
Published on: January 2, 2013
18.0K
Impact of input volume on red cell quality in deglycerolized RBCs using a modified ACP-215 protocol
Anita Howell1, Angela Hill1, Wanda Lefresne2
1Innovation and Portfolio Management, Canadian Blood Services, Edmonton, Alberta, Canada.
Transfusion
|December 8, 2024
Summary
A modified deglycerolization process using the LN235 kit can increase red blood cell concentrate (RBCC) hematocrit (Hct) for units exceeding 180 mL red cell mass. This method offers improved Hct without negatively impacting product quality.
Area of Science:
- Blood banking and transfusion medicine
- Cell processing technology
- Red blood cell preservation
Background:
- The ACP 215 automated cell processor is used for glycerolizing and deglycerolizing red cell concentrates (RCCs).
- It offers a closed system for extended post-thaw expiry compared to the COBE 2991.
- Lower post-deglycerolization hematocrits (Hct) were observed with the LN236 kit.
Purpose of the Study:
- To determine if a modified process using the smaller volume LN235 deglycerolization kit can increase final Hct.
- To assess potential deleterious effects on product characteristics with the LN235 kit.
Main Methods:
- Two proof-of-concept studies were conducted to establish feasibility and identify process modifications.
- A two-part study characterized the modified protocol.
- Investigated the impact of pre-cryopreservation storage duration, input red cell mass, and RCC production method.
Main Results:
- Using the LN235 kit with volume reduction for RCCs >180 mL red cell mass increased Hct by ~8%.
- Slightly lower recoveries were observed for large RCCs due to volume reduction.
- No other detrimental outcomes on product quality were noted.
Conclusions:
- The LN235 kit can be leveraged to increase post-deglycerolization Hct for RCCs exceeding 180 mL red cell mass.