Sampling and Pretreatment of Tooth Enamel Carbonate for Stable Carbon and Oxygen Isotope Analysis
Published on: August 15, 2018
In situ carbon isotopic analyses of magnesium-rich carbonates by LA-MC-ICP-MS at low mass resolution using an
1State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, 430074, China.
Abstract:
Accurate in situ carbon isotopic measurements of magnesium-rich carbonates using LA-MC-ICP-MS require effective correction for isobaric interference, particularly from doubly charged Mg ions that can induce δ13C deviations of several permil. This study focuses on optimizing gas parameters and developing robust correction strategies to improve the accuracy of δ13C measurements. Experimental results demonstrate that the introduction of nitrogen gas at a flow rate of 4-6 mL/min effectively doubles signal sensitivity while optimizing low helium (0.1-0.2 L/min) and high argon (1.0-1.1 L/min) flow rates enhances the signal-to-noise ratio and minimizes Mg2+ interference. Three correction approaches were evaluated: (1) simple peak stripping without mass bias correction, (2) peak stripping with mass bias correction using bracketed standards, and (3) iterative mass bias correction. The simple peak stripping approach is limited to samples with low Mg/C ratios (25Mg2+/12C+ ≤ 0.051 ‰). Bracketed standard calibration offers broader applicability but is affected by the instrumental mass bias factor (fMg), with long-term variations between 1.37 and 1.92 leading to δ13C deviations up to ∼2.35 ‰. This method performs well for carbonates with 25Mg2+/12C+ ratios below 0.139 ‰, aligning closely with IRMS results, but introduces inaccuracies for dolomite and magnesite. The iterative correction approach yielded the most accurate δ13C values, consistent with IRMS results, with deviations within 0.38 ‰ and improved external reproducibility. This method negates the need for prior determination of fMg, offering enhanced external reproducibility. Utilizing optimal gas flow conditions and iterative correction, spatial resolution of 90 μm was achieved, with external reproducibility of 0.52 ‰ (2SD), representing a marked improvement over previous analytical methods.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
12:03Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Resolution Mass Spectrometry (HRMS)
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Mass Analyzers: Overview
Mass Spectrometry: Isotope Effect