Related Experiment Video
Updated: Jun 4, 2025

Making, Testing, and Using Potassium Ion Selective Microelectrodes in Tissue Slices of Adult Brain
Published on: May 7, 2018
Comparative Study of Potassium Ion-Selective Electrodes with Solid Contact: Impact of Intermediate Layer Material on
Klaudia Morawska1, Szymon Malinowski2, Magdalena Wardak3
1Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland.
Abstract:
This paper presents a comparative study on the temperature resistance of solid-contact ion-selective electrodes, depending on the type of solid-contact material. Five types of potassium electrodes, with a valinomycin-based model membrane, were developed using different types of mediation layers, namely a conductive polymer (poly(3-octylthiophene-2,5-diyl) and a perinone polymer), multi-walled carbon nanotubes, copper(II) oxide nanoparticles, and a nanocomposite consisting of multi-walled carbon nanotubes and copper(II) oxide. We examined how the measurement temperature (10 °C, 23 °C, and 36 °C) affects the sensitivity, measurement range, detection limit, selectivity, as well as the stability and reversibility of the electrode potential. Electrodes modified with a nanocomposite (GCE/NC/ISM) and a perinone polymer (GCE/PPer/ISM) showed the best resistance to temperature changes. An almost Nernst response and a stable measurement range and the lowest detection limit values for each temperature were obtained for them. The introduction of mediation layers significantly improved the stability and potential reversibility of all the modified electrodes relative to the unmodified electrode (GCE/ISM). Still, it was the GCE/PPer/ISM and GCE/NC/ISM that stood out from the others, with stability of 0.11 and 0.12 µV/s for 10 °C, 0.05 and 0.08 µV/s for 23 °C, and 0.06 and 0.09 µV/s for 36 °C, respectively.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Potentiometry: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Ion-Exchange Chromatography