Related Experiment Video
Updated: Jun 4, 2025

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
The Influence of CLSM Magnification on the Measured Roughness of Differently Prepared Dental Materials
Martin Rosentritt1, Anne Schmutzler1, Sebastian Hahnel1
1Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany.
Abstract:
This in vitro study investigated how varying magnifications (5×, 10×, 20×, and 50×) using a confocal laser scanning microscope (CLSM) influence the measured surface roughness parameters, Ra/Sa and Rz/Sz, of various materials with two surface treatments. Cylindrical specimens (d ≈ 8 mm, h ≈ 3 mm, n = 10) from titanium, zirconia, glass-ceramic, denture base material, and composite underwent diamond treatment (80 μm; wet) and polishing (#4000; wet; Tegramin-25, Struers, G). The surface roughness parameters (Ra/Sa, Rz/Sz) were measured with a CLSM (VK-100, Keyence, J) at 5×, 10×, 20×, and 50× magnifications. Line roughness (Ra/Rz) was measured along a 1000 μm distance in three parallel lines, while area roughness (Sa/Sz) was evaluated over a 2500 μm × 1900 μm area. The statistical analysis included ANOVA, the Bonferroni post hoc test, and Pearson correlation (SPSS 29, IBM, USA; α = 0.05). Ra/Sa and Rz/Sz showed significant differences (p ≤ 0.001, ANOVA) across magnifications, with values decreasing as magnification increased, highest at 5× and lowest at 50×. Titanium, zirconia, and glass-ceramic showed significant measured roughness values from 5× to 50×. Denture base material and composite had lower measured roughness values, especially after polishing. Line and area roughness varied significantly, indicating that magnification affects measured values. Standardizing magnifications is essential to ensure comparability between studies. A 50× magnification captures more detailed profile information while masking larger defects.
More Related Videos
03:37Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Confocal Fluorescence Microscopy