Related Experiment Video
Updated: Jun 4, 2025

Data Acquisition and Analysis In Brainstem Evoked Response Audiometry In Mice
Published on: May 10, 2019
Abnormal-Sound Diagnosis for Kaplan Hydroelectric Generating Units Based on Continuous Wavelet Transform and Transfer
Yu Liu1, Zhuofei Xu1,2, Pengcheng Guo1
1School of Water Resources and Hydroelectric Engineering, Xi'an University of Technology, Xi'an 710048, China.
Abstract:
To realize abnormal-sound diagnosis in hydroelectric generating units, this study proposes a method based on continuous wavelet transform (CWT) and Transfer Learning (TL). A denoising algorithm utilizing spectral noise-gate technology is proposed to enhance fault characteristics in hydroelectric units. Subsequently, Continuous Wavelet Transform is applied to obtain frequency components, and the results are converted into a series of pseudo-color images to highlight information differences. A transfer model is subsequently developed for feature extraction, utilizing simplified fully connected layers to reduce modeling costs. The study optimizes key parameters during the signal-processing stage and achieves an improved parameter-setting scheme. Acoustic signals corresponding to four different fault states and a normal state are collected from a Kaplan hydroelectric generating unit in a hydropower station. The signal diagnosis accuracy rates before filtering are 84.83% and 95.14%. These rates significantly improved to 98.88% and 98.06%, respectively, demonstrating the effectiveness of the noise-reduction process. To demonstrate the superiority of the improved model in this work, a series of classic deep-learning models, including AlexNet, Resnet18, and MobileNetV3, are used for comparative analysis. The proposed method can effectively diagnose faults in Kaplan hydroelectric generating units with a high accuracy, which is crucial for the daily monitoring and maintenance of these units.
More Related Videos
06:01Semi-Automated Analysis of Peak Amplitude and Latency for Auditory Brainstem Response Waveforms Using R
Published on: December 9, 2022
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Related Concept Videos
Continuous -time Fourier Transform
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same...
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Sampling Continuous Time Signal
In the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: