Related Experiment Video
Updated: Jun 4, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Carbonization test and orthogonal polynomial regression analysis of steel fiber reclaimed concrete
Yahong Ding1, Zhongcai Lin1, Chunling Yan1,2,3
1School of Civil Engineering, Henan Polytechnic University, Jiaozuo, 455000, China.
Abstract:
To enhance the carbonation resistance of reclaimed concrete, several key factors affecting its performance were investigated. An orthogonal array L 16(4³ × 2⁶) was employed to design the carbonation tests for steel fiber (SF) reinforced concrete. The study included varying SF volume ratios, along with considerations of different concrete ages (T) and water-cement ratios (W/R). The effect of SF volume ratio, regenerated crude aggregate (RCA) replacement rate, W/R, and T on the carbonation resistance of recycled concrete was analyzed. The test results indicated a trend of increasing carbonation depth over time. However, a lower W/R ratio resulted in a reduced carbonation depth. Notably, a 50 % RCA replacement rate led to a shallower carbonation depth compared to other replacement rates. After 28 d, recycled concrete containing 1 % SF exhibited a carbonation depth that was 6.9 %, 1.5 %, 1.5 %, and 9.3 % lower than concrete with 0 %, 0.5 %, 1.5 %, and 2 % SF, respectively. Therefore, the incorporation of 1 % SF was found to be the most effective in improving carbonation resistance. Orthogonal polynomial regression analysis was employed to develop a regression equation relating carbonation depth to SF volume ratio, RCA replacement rate, W/R, and T. The regression coefficients were calculated and tested, leading to the identification of the optimal regression equation and its corresponding confidence interval.
More Related Videos
10:24Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Related Concept Videos
Fiber Reinforced Concrete
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Reinforcements in Concrete
Additives and Fillers in Concrete