Related Experiment Video
Updated: Jun 4, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Teamwork without talking: distributed system estimates maintain approximately centralized control of smart urban
Travis Adrian Dantzer1, Branko Kerkez1
1University of Michigan Civil and Environmental Engineering, 2350 Hayward St, Ann Arbor, 48104, Michigan, USA.
Abstract:
Real-time control of urban drainage systems (UDS) can reduce flood risk while enhancing water quality. However, internet-connected valves and weirs may become a liability during communications outages. Given that severe storms often cause both flooding and communications failures, it is critical that smart systems cope well with communications outages during these events. We propose a method to maintain approximately centralized predictive control of a UDS under intermittent communication by hosting approximations of the total system's dynamics and states on each networked microcontroller. This allows individual microcontrollers to act from an imperfect understanding of the total system, even when they have not communicated with the central server for several days. We show robustness to communications outages; maintaining centralized control in this case study when reporting only once every 7 days on average. We also examine the role of relative position within the network in determining the accuracy of each microcontroller's estimates of depths in the other storage basins. This investigation supports the idea that agents within a distributed control problem can make model-based inferences of total system conditions using their local measurements.
Related Concept Videos
Distribution Reliability and Automation
Primary Distribution
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...

