Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Stability of volatile organic compounds in thermal desorption tubes and in solution
Kristian J Kiland1, Lucas Martins1, Scott A Borden1
1Integrative Oncology, British Columbia Cancer Research Institute, Vancouver, British Columbia, Canada.
Abstract:
Exhaled breath volatile organic compounds (VOCs) are often collected and stored in sorbent tubes before thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) analysis. Information about the stability of VOCs during storage is needed to account for potential artifacts and monitor for losses. Additionally, information about the stability of VOC standards in solution is required to assess their performance as quality control and internal standards. We evaluated the stability of a standard mixture of 42 VOCs in dual-sorbent tubes containing Tenax® TA and Carbotrap 1TD over 60 d at commonly used storage conditions: room temperature (∼21 °C), 4 °C, and -80 °C. The same 42 VOCs were also evaluated for their stability in methanol over 60 d while stored at -20 °C. All samples were analyzed using TD-GC-MS. During storage, most VOCs were stable on sorbent after 60 d: 36/42 (86%), 39/42 (93%), and 41/42 (98%) had not statistically changed for room temperature, 4 °C and -80 °C, respectively, based on Spearman rank correlation coefficients and linear regression analysis. The isotopically labeled VOCs tested here are well-suited to serve as internal standards for pre-analysis or storage. Degradation of VOCs in solution was apparent after 60 d: 27/42 (64%) of VOCs had statistically decreased. The total VOC mixture had dropped to 90% of its original intensity after ∼22 d and a subset of VOCs typically used as internal standards dropped to 90% in ∼16 d. Analysts using similar mixtures should make a fresh solution at least every two weeks to ensure analytical accuracy. This study provides important insights into storage practices for both sorbent tubes and standard solutions, guiding analysts toward improved reliability and accuracy in exhaled breath analysis.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Volatilization
Distillation: Vapor–Liquid Equilibria
Flame Photometry: Lab
Ideal Solutions
Vapor Pressure Lowering
Dissolving a nonvolatile substance in volatile liquid results in a lowering of the liquid’s vapor pressure. This phenomenon can be explained by considering the effect of added solute molecules on the liquid's vaporization and condensation processes. To vaporize, solvent molecules must be present at the surface of the solution....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...