Late Gadolinium Enhancement of Nonischemic Cardiomyopathy at 5.0 T versus 3.0 T: A Crossover Design Study
Xianling Qian1, Shiyu Wang1, Yali Wu1
1From the Department of Radiology, Zhongshan Hospital, Fudan University, Xuhui District, Shanghai 200032, China (X.Q., S.W., Y.W., X.M., Y.C., H.L., H.J., M.Z.); Shanghai Institute of Medical Imaging, Shanghai, China (X.Q., S.W., Y.W., X.M., Y.C., H.L., H.J., M.Z.); and United Imaging Health Care Group, Shanghai, China (R.W., D.W., F.W., S.Z., J.H.).
Abstract:
Purpose To compare the acquisition time, image quality, and late gadolinium enhancement (LGE) visualization and quantification on phase-sensitive inversion recovery (PSIR) images using 5.0-T versus 3.0-T cardiac MRI. Materials and Methods In this prospective crossover study, 49 participants (mean ± SD age, 43.7 years ± 13.1; 39 men) suspected or diagnosed with nonischemic cardiomyopathy were enrolled from April 2023 to March 2024 and randomly assigned to group 1 (5.0-T followed by 3.0-T LGE cardiac MRI) or group 2 (3.0-T followed by 5.0-T LGE cardiac MRI). PSIR images were acquired at spatial resolutions of 1.2, 0.9, and 1.6 mm. Image quality and LGE were qualitatively evaluated using a five-point Likert scale by two readers, and signal-to-noise ratio, contrast-to-noise ratio, and LGE mass were quantitatively assessed. Bland-Altman plots were used to evaluate interreader agreement. Results There was no evidence of a difference in the acquisition time for obtaining a single-layer PSIR image at 5.0 T compared with 3.0 T (P > .05 for all), irrespective of resolutions at 1.2, 0.9, and 1.6 mm. The 5.0-T PSIR images demonstrated better image quality and LGE visualization compared with 3.0-T images, particularly at 1.2 mm (image quality: median 5 [IQR, 5-5] vs median 5 [IQR, 4-5]; P = .004; LGE score: median 5 [IQR, 5-5] vs median 4.25 [IQR, 4-5]; P < .001). No evidence of differences in image quality or LGE scores was found between 5.0-T and 3.0-T cardiac MRI at 1.6-mm resolution. Signal-to-noise ratio and contrast-to-noise ratio were higher on 5.0-T PSIR images across all resolutions compared with 3.0-T images (P < .001 for all), but no evidence of a difference was found in LGE mass measurements. Conclusion The study demonstrates that 5.0-T PSIR imaging offers better image quality and LGE visualization than 3.0-T PSIR, particularly at a 1.2-mm resolution, in individuals with nonischemic cardiomyopathy. Keywords: MRI, Cardiac, Heart, Comparative Studies, Nonischemic Cardiomyopathy, Late Gadolinium Enhancement, Phase-Sensitive Inversion Recovery Supplemental material is available for this article. ©RSNA, 2024.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
08:41Assessment of Cardiac Function and Myocardial Morphology Using Small Animal Look-locker Inversion Recovery SALLI MRI in Rats
Published on: July 19, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT