Automated Insulin Delivery in Older Adults with Type 1 Diabetes
Yogish C Kudva1, Robert J Henderson2, Lauren G Kanapka2
1Division of Endocrinology, Diabetes, Metabolism and Nutrition, Department of Internal Medicine, Mayo Clinic, Rochester, MN.
Background:
Older adults with type 1 diabetes are at risk for serious hypoglycemia. Automated insulin delivery can reduce risk but has not been sufficiently evaluated in this population.
Methods:
We conducted a multicenter, randomized crossover trial in adults older than or equal to 65 years of age with type 1 diabetes. Participants completed three 12-week periods of using hybrid closed loop, predictive low-glucose suspend, and sensor-augmented pump insulin delivery in a randomized order. The primary outcome was the percentage of time with continuous glucose monitoring glucose values less than 70 mg/dl.
Results:
Eighty-two participants between 65 and 86 years of age were randomly assigned: 45% were female; the baseline mean (±SD) glycated hemoglobin level was 7.2±0.9%; and the baseline percentage of time with glucose values less than 70 mg/dl was 2.49±1.78%. In the sensor-augmented pump, hybrid closed-loop, and predictive low-glucose suspend periods, percentages of time with glucose less than 70 mg/dl were 2.57±1.54%, 1.58±0.95%, and 1.67±0.96%, respectively. Compared with the sensor-augmented pump results, the mean difference with the hybrid closed-loop system was -1.05 percentage points (95% confidence interval [CI], -1.48 to -0.73 percentage points; P<0.001) and with the predictive low-glucose suspend system it was -0.93 percentage points (95% CI, -1.27 to -0.66 percentage points; P<0.001). Comparing a hybrid closed-loop system with a sensor-augmented pump, time in the range 70 to 180 mg/dl changed by 8.9 percentage points (95% CI, 7.4 to 10.4 percentage points) and the glycated hemoglobin level changed by 0.2 percentage points (95% CI, -0.3 to -0.1 percentage points). Serious adverse events were uncommon. Severe hypoglycemia occurred in 4% or less of participants; there were two hospitalizations for diabetic ketoacidosis.
Conclusions:
In older adults with type 1 diabetes, automated insulin delivery decreased hypoglycemia compared with sensor-augmented pump delivery. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number: NCT04016662.).
More Related Videos
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
06:27Accelerated Type 1 Diabetes Induction in Mice by Adoptive Transfer of Diabetogenic CD4+ T Cells
Published on: May 6, 2013
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Type 2 and Gestational
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...