Intra and Inter-Test Reliability of Isometric Hip Adduction Strength Test with Force Plates in Professional Soccer
Jorge Pérez-Contreras1,2, Juan Francisco Loro-Ferrer3, Pablo Merino-Muñoz4,5
1Escuela de Doctorado de La Universidad de Las Palmas de Gran Canaria (EDULPGC), 35016 Las Palmas, Spain.
Abstract:
Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. Purpose: To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players. Methods: Twenty-three professional male soccer players were evaluated on two occasions, 1 week apart. The force signal was collected using force plates (Pasco PS-2141), and the data processing was performed using Matlab software (R2023a, MathWorks, Natick, MA, USA). The peak force, interval RFD, peak RFD, peak force asymmetry and RFD were analyzed. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated to corroborate the intra- and inter-test reliability. In addition, the degree of agreement of the asymmetries was corroborated through the kappa index. Results: The peak force demonstrated an acceptable absolute reliability (CV < 10%) for the intra-test and test-retest condition, an excellent relative intra-test reliability and a good to moderate reliability for the test-retest reliability. However, the peak force asymmetry showed a moderate test-retest reliability and agreement. For the intra-test condition, the RFD variables demonstrate a moderate to excellent relative reliability; however, all demonstrate unacceptable absolute reliability (CV > 10%) in at least one of the evaluation sessions. A moderate to poor test-retest reliability and unacceptable absolute reliability were observed for all the RFD variables. Conclusions: The peak force is the variable with the highest intra- and inter-test reliability, so its use is recommended to longitudinally assess the maximum strength of the adductors in professional soccer players, but not the asymmetry orientation of the peak force. The RFD variables should be interpreted with caution due to their inconsistent reliability, and it is necessary to improve the methods used to achieve adequate reliability.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
Related Concept Videos
Reliability and Validity
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Testing Water Quality
Vebe Test
To conduct the test, concrete is placed into the slump cone. The concrete is filled in layers and...
Non-destructive Tests for Concrete Strength
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...