Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
A gamma-ray imaging method for multiple radionuclides and low-activity radioactive sources
Donghai Fan1, Rui Wu1, Dengke Wei1
1State Key Laboratory of SolidifiCation Processing, and MIIT Key Laboratory of Radiation Detection Materials and Devices, Northwestern Polytechnical University, Xi'an, 710072, China.
Abstract:
Gamma-ray coded-aperture imaging technology has important applications in the fields of nuclear security, isolated source detection, and the decommissioning of nuclear facilities. However, artifacts can reduce the quality of reconstructed images and affect the identification of the intensity and location of radioactive sources. In this paper, a gamma-ray coded-aperture imaging method based on primitive and reversed coded functions (PRCF) was proposed to reduce imaging artifacts. Building on this, the PRCF method was improved by integrating energy spectral information collected by the detector. By selecting energy intervals corresponding to characteristic energies of different radioactive sources for data filtering, the imaging capability of the PRCF method was further enhanced for multiple radioactive sources. Through simulation, the selection range of the correction factor in the PRCF method was determined. Single-source and multi-source imaging experiments were conducted using the self-built coded-aperture imaging system based on a CdZnTe pixel detector, and the selection criteria for the energy interval ranges of different radioactive sources were established. Compared with the conventional maximum likelihood expectation maximization (MLEM) method, the improved PRCF method not only effectively reduced artifacts and enhanced the imaging quality, but also ensured the accuracy of imaging results for multiple radioactive sources. Moreover, through imaging experiments using low-activity 137Cs and high-activity 241Am and 133Ba, it was demonstrated that the PRCF method can achieve low-count imaging in complex environments, providing a solution for imaging low-activity radioactive sources.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
X-ray Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Isotopes and Radioisotopes
An isotope containing...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...