Related Experiment Video
Updated: May 7, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Enhanced photovoltaic panel diagnostics through AI integration with experimental DC to DC Buck Boost converter
Chouaib Labiod1,2, Redha Meneceur3, Ali Bebboukha3
1Department of Mechanical Engineering, University of El Oued, El Oued, 39000, Algeria.
Abstract:
Health monitoring and analysis of photovoltaic (PV) systems are critical for optimizing energy efficiency, improving reliability, and extending the operational lifespan of PV power plants. Effective fault detection and monitoring are vital for ensuring the proper functioning and maintenance of these systems. PV power plants operating under fault conditions show significant deviations in current-voltage (I-V) characteristics compared to those under normal conditions. This paper introduces a diagnostic methodology for photovoltaic panels using I-V curves, enhanced by new techniques combining optimization and classification-based artificial intelligence. The research is organized into two key sections. The first section outlines the implementation of a DC/DC buck-boost converter, which is designed to extract and display real-time data from the PV system based on actual (I-V) measurements. The second section focuses on the comprehensive processing of the experimental dataset, where the Harris Hawks Optimization (HHO) algorithm is combined with machine learning methods to identify the most critical features. The HHO algorithm is combined with an advanced machine learning model, XGBoost, to accurately detect faults within the PV system. The proposed HHO-XGBoost algorithm achieves an impressive accuracy of 99.49%, outperforming other classification-based artificial intelligence methods in fault detection. In validation and comparison with previous approaches, the HHO-XGBoost model consistently outperforms established methods such as GADF-ANN, PCA-SVM, PNN, and Fuzzy Logic, achieving an overall accuracy of 98.48%. This outstanding performance confirms the model's effectiveness in accurately diagnosing PV system conditions, further validating its robustness and reliability in fault detection and classification.
More Related Videos
09:19In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for CuIn,GaSe2 Solar Cells
Published on: October 3, 2018
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
Related Concept Videos
Power Factor Correction
Voltage Doubler Circuit
Full wave rectifier
Bridge rectifier
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Half wave rectifier
DC Generator