Related Experiment Video
Updated: Jul 21, 2026

A Large Lateral Craniotomy Procedure for Mesoscale Wide-field Optical Imaging of Brain Activity
Published on: May 7, 2017
Intraoperative Skull Fracture During Halo Application in Subcranial Le Fort III: Strategies for Managing a Rare
Stephen D Moreno1, Samuel D Raffaelli2, Robert H Liu3
1Department of Oral and Maxillofacial Surgery, Division of Pediatric Craniofacial Surgery, Naval Medical Center San Diego, San Diego, CA.
None:
External rigid distraction is an established method for achieving subcranial Le Fort III advancement in severe syndromic craniosynostosis. Craniofacial surgeons commonly use halo-type devices for these corrections, as they allow for multiple vectors of pull and facilitate larger midfacial advancements. Although most complications related to their use involve pin displacement or infection, rare complications such as skull fractures have been reported. At 3 months of age, a patient with Apert Syndrome underwent endoscopic-assisted craniectomies for bilateral coronal craniosynostosis. After a year of helmet therapy, he developed pansynostosis and required fronto-orbital advancement. Later at the age of 6, a Le Fort III distraction using a RED II rigid external distractor was performed to address his midfacial hypoplasia, exorbitism, and severe obstructive sleep apnea. While placing the RED II distractor, a shift in the device was noted upon pin fixation, raising suspicion for a unilateral depressed skull fracture. Although computed tomography imaging revealed pin displacement, there was no clinical indication for immediate repair. Given the surgical and psychological burden this could have on the patient, the decision was made to leave the RED II device in place and proceed with the distraction. After distraction and an 8-week latency period for complete consolidation of the facial bony architecture, the RED II device was removed, and the skull fracture was repaired. In patients with multi-operated skulls and residual cranial defects, halo-type devices may present an increased risk of skull fractures. This report discusses alternatives in the literature and presents an example of a rare complication successfully managed with delayed repair.
More Related Videos
09:16Use of a Wireless Video-EEG System to Monitor Epileptiform Discharges Following Lateral Fluid-Percussion Induced Traumatic Brain Injury
Published on: June 21, 2019
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Mitral Stenosis III: Medical Management
Endocarditis III: Medical Management
Pericarditis III: Medical Management
Aneurysm III: Interprofessional Care