Related Experiment Video
Updated: May 7, 2025

Screening for Thermotoga maritima Membrane-Bound Pyrophosphatase Inhibitors
Published on: November 23, 2019
Thermotolerance screening of Brassica carinata genotypes using in vitro seed germination assay
Leelawattie Persaud1, Naflath Thenveettil1, Ramdeo Seepaul2
1Department of Plant and Soil Sciences, 117 Dorman Hall, Box 9555, Mississippi State University, Mississippi State, MS, 39762, USA.
Abstract:
Temperature is a fundamental factor influencing the processes of seed germination. Investigating the response of carinata to thermal stress and establishing a dependable and efficient method for screening thermotolerance will enhance breeding programs and model applications. We assessed the response of 12 carinata genotypes to a range of eight temperatures, spanning from 8 to 37 °C, throughout the germination process. A four-parameter Weibull function effectively characterized the seed germination time course across various temperatures and genotypes. Quadratic functions effectively characterize the maximum seed germination and the rate of seed germination as a function of temperature across various genotypes. The average cardinal temperatures recorded were -0.14, 20.41, and 40.70 °C for maximum seed germination, while the temperatures for seed germination rate were 5.30 °C, 24.51 °C, and 43.71 °C, corresponding to minimum, optimum, and maximum conditions, respectively. A notable variation was observed in maximum seed germination, seed germination rate, and cardinal temperatures across different genotypes. The specified parameters were employed to screen the genotypes for their thermotolerance capabilities. The analysis of principal components and the cumulative response indices effectively characterized carinata genotypes for high- and low-temperature tolerance exhibiting distinct characteristics. The AX17004 was identified as a genotype with significant tolerance to high temperatures, whereas AX17009 demonstrated remarkable tolerance to low temperatures. In contrast, AX17002 exhibited sensitivity to both high and low-temperature stress. According to the classification of breed types, both double haploid and hybrid groups revealed consistent thermotolerance responses during the germination phase. In contrast, the inbred group exhibited a wider response cluster to both minimum and maximum temperatures. The in vitro assay method presents a cost-effective approach for evaluating thermotolerance in carinata genotypes.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

