A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Development and evaluation of an in-beam PET system for proton therapy monitoring
Qiuhui Ma1, Dengyun Mu2, Ruilin Zhang2
1The School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, People's Republic of China.
Abstract:
Objective. In-beam positron emission tomography (PET) has important development prospects in real-time monitoring of proton therapy. However, in the beam-on operation, the high bursts of radiation events pose challenges to the performance of the PET system.Approach. In this study, we developed a dual-head in-beam PET system for proton therapy monitoring and evaluated its performance. The system has two PET detection heads, each with6×3Plug&Imaging (PnI) detection units. Each PnI unit consists of6×6lutetium-yttrium oxyorthosilicate crystal arrays. The size of each crystal strip is3.95×3.95×20 mm3, which is one-to-one coupled with a silicon photomultiplier. The overall size of the head is15.3×7.65 cm2.Main results. The in-beam PET system achieved a single count rate of 48 Mcps at the activity of 144.9 MBq, an absolute sensitivity of 2.717%, and a spatial resolution of approximately 2.6 mm (full width at half maximum) at the center of the field-of-view. When imaging a Derenzo phantom, the system could resolve rods with a diameter of 2.0 mm. Time-dynamic [18F]-Fluorodeoxyglucose mouse imaging was performed, demonstrating the metabolic processes in the mouse. This shows that the in-beam PET system has the potential for biology-guided proton therapy. The in-beam PET system was used to monitor the range of a 130 MeV proton beam irradiating a polymethyl methacrylate (PMMA) phantom, with a beam intensity of6.0×109p s-1and an irradiation duration of one minute. PET data were acquired only during the one-minute irradiation. We simulated the range shift by moving the PMMA and adding an air gap, showing that the error between the actual and the measured range is less than 1 mm.Significance. The results demonstrate that the system has a high count rate and the capability of range monitoring in beam-on operation, which is beneficial for achieving real-time range verification of proton beams in the future.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...