Automated estimation of individualized organ-specific dose and noise from clinical CT scans
Sen Wang1, Maria Jose Medrano1, Abdullah Al Zubaer Imran1,2
1Department of Radiology, Stanford University, Stanford, CA 94305, United States of America.
Abstract:
Objective. Radiation dose and diagnostic image quality are opposing constraints in x-ray computed tomography (CT). Conventional methods do not fully account for organ-level radiation dose and noise when considering radiation risk and clinical task. In this work, we develop a pipeline to generate individualized organ-specific dose and noise at desired dose levels from clinical CT scans.Approach. To estimate organ-specific dose and noise, we compute dose maps, noise maps at desired dose levels and organ segmentations. In our pipeline, dose maps are generated using Monte Carlo simulation. The noise map is obtained by scaling the inserted noise in synthetic low-dose emulation in order to avoid anatomical structures, where the scaling coefficients are empirically calibrated. Organ segmentations are generated by a deep learning-based method (TotalSegmentator). The proposed noise model is evaluated on a clinical dataset of 12 CT scans, a phantom dataset of 3 uniform phantom scans, and a cross-site dataset of 26 scans. The accuracy of deep learning-based segmentations for organ-level dose and noise estimates was tested using a dataset of 41 cases with expert segmentations of six organs: lungs, liver, kidneys, bladder, spleen, and pancreas.Main results. The empirical noise model performs well, with an average RMSE approximately 1.5 HU and an average relative RMSE approximately 5% across different dose levels. The segmentation from TotalSegmentator yielded a mean Dice score of 0.8597 across the six organs (max = 0.9315 in liver, min = 0.6855 in pancreas). The resulting error in organ-level dose and noise estimation was less than 2% for most organs.Significance. The proposed pipeline can output individualized organ-specific dose and noise estimates accurately for personalized protocol evaluation and optimization. It is fully automated and can be scalable to large clinical datasets. This pipeline can be used to optimize image quality for specific organs and thus clinical tasks, without adversely affecting overall radiation dose.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020