Related Experiment Video
Updated: Jun 3, 2025

High-throughput Screening for Small-molecule Modulators of Inward Rectifier Potassium Channels
Published on: January 27, 2013
A Simple and Rapid "Turn-On" Fluorescent Probe Based on Binuclear Schiff Base for Zn2+ and Its Application in Cell
Jinghui Cheng1, Yi Li1, Zhiye Zhu1
1Key Laboratory of Chemo/Biosensing and Detection of Xuchang, Key Laboratory of Micro-Nano Materials for Energy Storage and Conversion of Henan Province, Henan Joint International Research Laboratory of Nanomaterials for Energy and Catalysis, College of Chemical and Materials Engineering, Xuchang University, Xuchang 461000, China.
Abstract:
A series of colorful binuclear Schiff bases derived from the different diamine bridges including 1,2- ethylenediamine (bis-Et-SA, bis-Et-4-NEt2, bis-Et-5-NO2, bis-Et-Naph), 1,2-phenylenediamine (bis-Ph-SA, bis-Ph-4-NEt2, bis-Ph-5-NO2, bis-Ph-Naph), dicyano-1,2-ethenediamine (bis-CN-SA, bis-CN-4-NEt2, bis-CN-5-NO2, bis-CN-Naph) have been designed and prepared. The optical properties of these binuclear Schiff base ligands were fully determined by UV-Vis absorption spectroscopy, fluorescence emission spectroscopy, and time-dependent-density functional theory (TD-DFT) calculations. The inclusion of D-A systems and/or π-extended systems in these binuclear Schiff base ligands not only enables adjustable RGB light absorption and emission spectra (300~700 nm) but also yields high fluorescence quantum efficiencies of up to 0.84 in MeCN solution. Then, with the ESIPT (excited-state intramolecular proton transfer) property, fluorescence analysis showed that the probe bis-Et-SA and bis-Ph-SA could recognize Zn2+ via the "turn on" mode in the MeCN solution. During the detection process, bis-Et-SA and bis-Ph-SA demonstrate rapid response and high selectivity upon the addition of Zn2+. The coordination of Zn2+ with the oxygen atom and Schiff base nitrogen atom in a tetrahedral geometry is confirmed by Job's plot, FT-IR, and 1H NMR spectroscopy. In addition, the paper test and Hela cells were successfully carried out to detect Zn2+. Moreover, the sensitivity of bis-Et-SA and bis-Ph-SA is much better than that of those Schiff base ligands containing only one chelating unit [O^N^N^O].
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Photoluminescence: Applications
FISH - Fluorescent In-situ Hybridization