Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

¹H NMR Signal Integration: Overview00:58

¹H NMR Signal Integration: Overview

1.3K
The intensity of a signal, which can be represented by the area under the peak, depends on the number of protons contributing to that signal. The area under each peak is shown as a vertical line called an integral, with the integral value listed under it, as seen in the proton NMR spectrum of benzyl acetate. Each integral value is divided by the smallest integral value to obtain the ratio of the number of protons producing each signal. The ratio reveals the relative number of protons and not...
1.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The Noise Reduction Algorithm May Not Compensate for the Degradation in Output Signal-to-Noise Ratio Caused by Wide Dynamic Range Compression.

American journal of audiology·2024
Same author

Verification of Estimated Output Signal-to-Noise Ratios From a Phase Inversion Technique Using a Simulated Hearing Aid.

American journal of audiology·2023
Same author

Differences in Auditory Perception Between Young and Older Adults When Controlling for Differences in Hearing Loss and Cognition.

Trends in hearing·2022
Same author

PAMAM dendrimers undergo pH responsive conformational changes without swelling.

Journal of the American Chemical Society·2009
Same author

[Expression of mammalian target of rapamycin and p70 S6 kinase in rabbit periodontal tissues remodeling during orthodontic tooth movement].

Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology·2009
Same author

Comparison of bolus remifentanil versus bolus fentanyl for blunting cardiovascular intubation responses in children: a randomized, double-blind study.

Chinese medical journal·2009

Related Experiment Video

Updated: Jun 3, 2025

A Low Cost Setup for Behavioral Audiometry in Rodents
09:23

A Low Cost Setup for Behavioral Audiometry in Rodents

Published on: October 16, 2012

12.7K

Estimating the Tinnitus Spectrum: A Comparison Between At-Home and Laboratory Measurements.

Jennifer J Lentz1,2, Yi Liu1,3

  • 1Department of Speech, Language and Hearing Sciences, Indiana University, Bloomington.

American Journal of Audiology
|January 8, 2025
PubMed
Summary

This study shows that measuring tinnitus pitch at home is a viable option. At-home tinnitus assessments can speed up clinical evaluations and support remote treatment strategies.

More Related Videos

Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses
14:05

Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses

Published on: January 23, 2017

29.1K
Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
07:32

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects

Published on: September 1, 2016

12.6K

Related Experiment Videos

Last Updated: Jun 3, 2025

A Low Cost Setup for Behavioral Audiometry in Rodents
09:23

A Low Cost Setup for Behavioral Audiometry in Rodents

Published on: October 16, 2012

12.7K
Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses
14:05

Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses

Published on: January 23, 2017

29.1K
Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
07:32

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects

Published on: September 1, 2016

12.6K

Area of Science:

  • Audiology
  • Medical Devices
  • Digital Health

Background:

  • Tinnitus is a common auditory condition.
  • Accurate tinnitus pitch measurement is crucial for effective management.
  • Current methods often require in-lab assessments.

Purpose of the Study:

  • To establish proof of concept for at-home tinnitus spectrum measurements.
  • To evaluate the feasibility of remote tinnitus pitch assessment.

Main Methods:

  • Nineteen participants completed tinnitus pitch similarity ratings in laboratory and at-home settings.
  • At-home tests utilized personal computers and headphones.
  • Data analyzed using linear regression and Bland-Altman plots for common frequencies (500-8000 Hz).

Main Results:

  • Tinnitus spectra shapes were similar between lab and home settings for 14 of 19 participants.
  • Regression analysis showed significantly positive slopes, indicating comparable spectral shapes.
  • Test-retest reliability was consistent in both environments for repeated measures.

Conclusions:

  • The pitch similarity rating method shows potential for at-home tinnitus pitch measurement.
  • At-home assessments could streamline clinical evaluations and complement remote treatment.