Related Experiment Video
Updated: Jul 14, 2026

Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
Does a priming warm-up influence the incidence of during a ramp test and verification phase?
JianBo Qiao1, Paul Rosbrook1, Daniel K Sweet1
1Center for Research and Education in Special Environments, Department of Exercise and Nutrition Sciences, University at Buffalo, Buffalo, NY, United States of America.
Objective:
This study compared the effects of two different warm-up protocols (normal vs. priming) on the oxygen plateau () incidence rate during a ramp test. It also compared the cardiopulmonary responses during the ramp test and subsequent verification phase.
Methods:
Eleven recreational cyclists performed two experimental visits. The first visit required a normal warm-up (cycling at 50 W for 10 min) followed by the ramp test (30 W.min-1) and supramaximal verification phase with 30 min rest between tests. The second visit required a priming warm-up (cycling at 50 W for 4 min increasing to 70% difference between the gas exchange threshold [GET] and maximum work rate [WRmax] for 6 min) followed by the same protocol as in the first visit. Physiological responses were collected during the exercise and compared. Oxygen kinetics ( Kinetics) and incidence rate were determined during the ramp tests for both visits.
Results:
As planned, following the warm-up the priming visit experienced greater physiological response. However, the incidence rate of during the ramp test was the same between visits (73%), and maximal oxygen uptake was not different between visits after the ramp test (normal, 4.0 ± 0.8; primed, 4.0 ± 0.7 L·min-1, p = 0.230) and verification phase (normal, 3.8 ± 0.6; primed, 3.8 ± 0.7 L·min-1, p = 0.924) using a Holm-Bonferroni correction for controlling family-wise error rate. Kinetics were not different between visits during the ramp test (normal, 10.8 ± 1.1; primed, 10.8 ± 1.2 mL·min-1·W-1, p = 0.407). The verification phase confirmed in 100% for both the normal and priming visits.
Conclusion:
Our hypothesis that a priming warm-up facilitates the incidence rate of during a ramp test is not supported by the results. The verification phase remains a prudent option when determining a 'true' is required.