Establishing cutoff values for visual amyloid positivity in [18F]flutemetamol PET
Yong-Jin Park1, So Young Moon2, Joon-Kee Yoon1
1Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, Korea.
Background:
This study aimed to establish the optimal cutoff values for visual amyloid positivity using standardized uptake value ratios (SUVRs) in [18F]flutemetamol (FMM) positron emission tomography (PET) imaging. Given the variability in amyloid assessment, our goal was to determine cutoff values that enhance diagnostic accuracy and assist clinicians in reliably identifying amyloid positivity.
Results:
The identified cutoff values for visual amyloid positivity were > 1.6 for the cerebellar gray matter, > 1.38 for the whole cerebellum, and > 0.63 for the pons, yielding high sensitivity (95.5%, 94.5%, and 95.8%, respectively) and specificity (91.2%, 94.3%, and 95.2%, respectively).
Conclusions:
The SUVR cutoff values demonstrated excellent diagnostic performance, supporting their clinical use in assessing visual amyloid positivity in [18F]FMM PET imaging.